Sign In | Join Free | My burrillandco.com
Home > MTL Instruments >

MTL4549 MTL4500 MTL Instruments Intrinsically Safe Isolators

Achievers Automation Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap MTL4549 MTL4500 MTL Instruments Intrinsically Safe Isolators from wholesalers
     
    Buy cheap MTL4549 MTL4500 MTL Instruments Intrinsically Safe Isolators from wholesalers
    • Buy cheap MTL4549 MTL4500 MTL Instruments Intrinsically Safe Isolators from wholesalers
    • Buy cheap MTL4549 MTL4500 MTL Instruments Intrinsically Safe Isolators from wholesalers
    • Buy cheap MTL4549 MTL4500 MTL Instruments Intrinsically Safe Isolators from wholesalers
    • Buy cheap MTL4549 MTL4500 MTL Instruments Intrinsically Safe Isolators from wholesalers

    MTL4549 MTL4500 MTL Instruments Intrinsically Safe Isolators

    Ask Lasest Price
    Brand Name : MTL
    Model Number : MTL4549
    Certification : HART
    Price : Negotiate
    Payment Terms : T/T
    Supply Ability : 1000pcs per week
    Delivery Time : stock
    • Product Details
    • Company Profile

    MTL4549 MTL4500 MTL Instruments Intrinsically Safe Isolators

    MTL4549 - MTL 4500 Intrinsically Safe Isolators


    MTL4549/C/Y - MTL5549/Y ISOLATING DRIVER two-channel, for 4–20mA, HART® valve positioners with line fault detection The MTLx549 accepts 4/20mA floating signals from safe-area controllers to drive 2 current/pressure converters (or any other load up to 800Ω) in a hazardous area. For HART valve positioners, the module also permits bi-directional transmission of digital communication signals. Process controllers with a readback facility can detect open or short circuits in the field wiring: if these occur, the current taken into the terminals drops to a preset level. The MTL4549C and MTLx549Y are very similar to the MTLx549 except that they provide open circuit detection only (i.e. no short-circuit detection).


    • Number of channels
    Two
    • Location of I/P converter
    Zone 0, IIC, T4–6 hazardous area if suitably certified
    Div. 1, Group A, hazardous location
    • Working range
    4 to 20mA
    • Digital signal bandwidth
    500Hz to 10kHz
    • Maximum load resistance
    800Ω (16V at 20mA)
    • Minimum load resistance
    90Ω (short-circuit detection at < 50Ω)
    • Output resistance
    > 1MΩ
    • Under/over range capability
    Under range = 1mA
    Over range = 24mA (load ≤ 520Ω)
    • Input and output circuit ripple
    <40µA peak-to-peak
    • Communications supported
    HART
    • Transfer accuracy at 20°C
    Better than 20µA
    • Temperature drift
    < 1.0µA/°C
    • Input characteristics
    Normal :< 6.0V
    Open-circuit: < 0.9mA
    Short-circuit :< 0.9mA
    • Response time
    Settles within 200µA of final value within 100ms
    • LED indicator
    Green: power indication
    • Maximum current consumption (with 20mA signals into 250Ω load)
    70mA at 24V dc
    • Power dissipation within unit (with 20mA signals into 250Ω load)
    1.6W at 24V
    • Safety description (each channel)
    Uo=28V Io=93mA Po=0.65W Um = 253V rms or dc


    MTL4549 MTL4500 MTL Instruments Intrinsically Safe Isolators


    HCU16MTL5521MTL4575
    HCU3700MTL5522MTL4646Y
    HM64RIB20-1.0MTL5531MTL4850
    HM64RIB20-1.5MTL5532MTL4851
    HMM64MTL5541MTL4852
    HMRIB16-1.0MTL5541SMTL5018
    HMS64MTL5544MTL5032
    HTP-SC32MTL5544DMTL5042
    MTL4044DMTL5546MTL5044
    MTL4511MTL5546YMTL5049
    MTL4516MTL5561MTL5511
    MTL4516CMTL5573MTL5514D
    MTL4521MTL5575MTL5516
    MTL4541MTL5582BMTL5516C
    MTL4541MTL7728+MTL7787P+
    MTL4544MTL7756ACMTLCPS16
    MTL4544DMTL7760ACNJ5-18GK-N
    MTL4546YMTL7761PACSD150X
    MTL4549YMTL7765ACSD32