Sign In | Join Free | My burrillandco.com
Home > Pepperl Fuchs Safety Barrier >

Pepperl Fuchs Fieldbus Barrier R4D0-FB-IA12.0 Supports Plug-In Surge Protectors

Achievers Automation Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Pepperl Fuchs Fieldbus Barrier R4D0-FB-IA12.0 Supports Plug-In Surge Protectors from wholesalers
     
    Buy cheap Pepperl Fuchs Fieldbus Barrier R4D0-FB-IA12.0 Supports Plug-In Surge Protectors from wholesalers
    • Buy cheap Pepperl Fuchs Fieldbus Barrier R4D0-FB-IA12.0 Supports Plug-In Surge Protectors from wholesalers
    • Buy cheap Pepperl Fuchs Fieldbus Barrier R4D0-FB-IA12.0 Supports Plug-In Surge Protectors from wholesalers
    • Buy cheap Pepperl Fuchs Fieldbus Barrier R4D0-FB-IA12.0 Supports Plug-In Surge Protectors from wholesalers
    • Buy cheap Pepperl Fuchs Fieldbus Barrier R4D0-FB-IA12.0 Supports Plug-In Surge Protectors from wholesalers

    Pepperl Fuchs Fieldbus Barrier R4D0-FB-IA12.0 Supports Plug-In Surge Protectors

    Ask Lasest Price
    Brand Name : PEPPERL FUCHS
    Model Number : R4D0-FB-IA12.0
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 100pcs per month
    Delivery Time : Negotiable
    • Product Details
    • Company Profile

    Pepperl Fuchs Fieldbus Barrier R4D0-FB-IA12.0 Supports Plug-In Surge Protectors

    Pepperl Fuchs Fieldbus Barrier R4D0-FB-IA12.0 Supports plug-in surge protectors

    8 ... 12 outputs Ex ia IIC, FISCO and Entity

    Advanced fault isolation and diagnostics at the spur

    FieldBarrier in Zone 1/Div. 2

    Instruments in Zone 0...1/Div. 1

    For FOUNDATION Fieldbus H1 and PROFIBUS PA

    Supports plug-in surge protectors

    Very compact, small footprint

    Designed for high reliability

    General specifications


    Fieldbus barrier, module for DIN rail mounting

    General specifications

    Design / Mounting Cabinet installation

    Installation in hazardous area Zone 1 / Div. 2

    Fieldbus connection

    Power dissipation see table 1

    Main cable (Trunk)

    Rated voltage 16 ... 32 V DC ,

    min. 15 V in case of brown out

    Rated current trunk IN to trunk OUT max. 2 A see table 1

    Cable shield grounding option Capacitive via 5.7 nF

    Direct

    Voltage drop trunk IN to trunk OUT 100 mV max.

    Number of couplers max. 3 per segment

    Reverse polarity protection Built-In

    Outputs

    Number of outputs 8, 10 or 12

    Number of devices per output 1

    Cable length 120 m

    Rated voltage 10 ... 14 V

    Rated current max. 43 mA at one spur ,

    max. 320 mA total current at all spurs

    Short-circuit current 53 mA , 1 mA in fallback state

    Cable shield grounding option Capacitive via 4.4 nF

    Surge protection Trunk overvoltage protection if voltage exceeds typ. 39 V, max. 41 V

    Diagnostic and Protection Features

    Fault Isolation Short Circuit Current Limitation at spurs

    Bounce Protection at spurs

    Signal inhibit at spurs

    Physical Layer Diagnostic Signal level at spurs

    Signal jitter at spurs

    Noise level at spurs

    Indicators/operating means

    Switch S1 ON: diagnostic alarms activated

    S2 ON: diagnostic warnings activated

    S3-S8: not used

    LED PWR green: Fieldbus voltage > 16 V

    LED COM/ERR yellow flashing: fieldbus communication and physical layer status ,

    red: Hardware error

    LED SPURS red: 2 Hz flashing in short-circuit condition

    Galvanic isolation

    Main wire/outputs isolation is not affected by interference according to EN 60079-11, voltage peak value 375 V

    Output/Output No Isolation

    Directive conformity

    Electromagnetic compatibility

    Directive 2014/30/EU EN 61326-1:2013

    Standard conformity

    Electromagnetic compatibility NE 21:2011

    Degree of protection IEC/EN 60529

    Fieldbus standard IEC 61158-2

    Climatic conditions IEC 60721

    Shock resistance EN 60068-2-27

    Vibration resistance EN 60068-2-6

    Ambient conditions

    Ambient temperature -40 ... 70 °C (-40 ... 158 °F)

    Storage temperature -40 ... 85 °C (-40 ... 185 °F)

    Relative humidity < 95 % non-condensing

    Shock resistance 15 g 11 ms

    Vibration resistance 1 g , 10 ... 150 Hz

    Corrosion resistance acc. to ISA-S71.04-1985, severity level G3

    Mechanical specifications

    Connection type screw terminal , pluggable or spring terminal , pluggable

    Core cross section see table 2

    Housing material Polycarbonate

    Degree of protection IP20

    Mass 2100 g

    Dimensions see dimensions

    Mounting DIN rail mounting

    Data for application in connection with hazardous areas

    EU-type examination certificate BVS 13 ATEX E 121 X

    Marking Ex-Hexagon II 2(1)G Ex eb ib mb [ia Ga] IIC T4 Gb

    Ex-Hexagon II (1)D [Ex ia Da] IIIC

    Ex-Hexagon I (M1) [Ex ia Ma] I

    Main cable (Trunk)

    Maximum safe voltage Um 253 V AC

    Outputs in accordance to FISCO and Entity

    Power 1.063 W

    Voltage 17.1 V

    Current 248.55 mA

    Inductance gas group IIC 470 µH ,

    gas group IIB 2 mH

    Capacitance gas group IIC 367 nF ,

    gas group IIB 2.15 µF

    Directive conformity

    Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-18:2015

    International approvals

    CSA approval CSA 14.70004139

    Control drawing 116-0400

    Approved for Class I, Division 2, Groups A, B, C, D T4

    Class I, Zone 1, AEx/Ex e ib mb [ia Ga] IIC T4 Gb

    Class I, Zone 1, AEx/Ex e ib mb [ia IIC Da] IIC T4 Gb

    Associated equipment for Class I, Division 1 Groups A, B, C, D

    Associated equipment for Class II, Division 1 Groups E, F, G

    Associated equipment for Class III, Division 1

    IECEx approval IECEx BVS 13.0119X

    Approved for Ex eb ib mb [ia Ga] IIC T4 Gb

    [Ex ia Da] IIIC

    [Ex ia Ma] I


    Pepperl Fuchs Fieldbus Barrier R4D0-FB-IA12.0 Supports Plug-In Surge Protectors


    Quality Pepperl Fuchs Fieldbus Barrier R4D0-FB-IA12.0 Supports Plug-In Surge Protectors for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Achievers Automation Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)