Sign In | Join Free | My burrillandco.com
Home > Pepperl Fuchs Safety Barrier >

Pepperl Fuchs Switch Amplifier KFD2-SR2-Ex2.W Reversible mode of operation

Achievers Automation Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Pepperl Fuchs Switch Amplifier KFD2-SR2-Ex2.W Reversible mode of operation from wholesalers
     
    Buy cheap Pepperl Fuchs Switch Amplifier KFD2-SR2-Ex2.W Reversible mode of operation from wholesalers
    • Buy cheap Pepperl Fuchs Switch Amplifier KFD2-SR2-Ex2.W Reversible mode of operation from wholesalers
    • Buy cheap Pepperl Fuchs Switch Amplifier KFD2-SR2-Ex2.W Reversible mode of operation from wholesalers
    • Buy cheap Pepperl Fuchs Switch Amplifier KFD2-SR2-Ex2.W Reversible mode of operation from wholesalers
    • Buy cheap Pepperl Fuchs Switch Amplifier KFD2-SR2-Ex2.W Reversible mode of operation from wholesalers

    Pepperl Fuchs Switch Amplifier KFD2-SR2-Ex2.W Reversible mode of operation

    Ask Lasest Price
    Brand Name : PEPPERL FUCHS
    Model Number : KFD2-SR2-Ex2.W
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 100pcs per month
    Delivery Time : Negotiable
    • Product Details
    • Company Profile

    Pepperl Fuchs Switch Amplifier KFD2-SR2-Ex2.W Reversible mode of operation

    Pepperl Fuchs Switch Amplifier KFD2-SR2-Ex2.W

    2-channel isolated barrier

    24 V DC supply (Power Rail)

    Dry contact or NAMUR inputs

    Relay contact output

    Line fault detection (LFD)

    Reversible mode of operation

    Up to SIL 2 (SC 3) acc. to IEC/EN 61508

    General specifications

    Signal type Digital Input

    Functional safety related parameters

    Safety Integrity Level (SIL) SIL 2

    Systematic capability (SC) SC 3

    Supply

    Connection Power Rail or terminals 14+, 15-

    Rated voltage 19 ... 30 V DC

    Ripple ≤ 10 %

    Rated current ≤ 50 mA

    Power dissipation ≤ 1 W

    Power consumption ≤ 1 W

    Input

    Connection side field side

    Connection terminals 1+, 2+, 3-; 4+, 5+, 6-

    Rated values acc. to EN 60947-5-6 (NAMUR)

    Open circuit voltage/short-circuit current approx. 8 V DC / approx. 8 mA

    Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA

    Line fault detection breakage I ≤ 0.1 mA , short-circuit I > 6 mA

    Pulse/Pause ratio min. 20 ms / min. 20 ms

    Output

    Connection side control side

    Connection output I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12

    Output I, II signal, relay

    Contact loading 250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 40 V DC/2 A resistive load

    Minimum switch current 2 mA / 24 V DC

    Energized/De-energized delay approx. 20 ms / approx. 20 ms

    Mechanical life 107 switching cycles

    Collective error message Power Rail

    Transfer characteristics

    Switching frequency ≤ 10 Hz

    Galvanic isolation

    Input/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

    Input/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

    Output/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

    Output/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

    Indicators/settings

    Display elements LEDs

    Control elements DIP switch

    Configuration via DIP switches

    Labeling space for labeling at the front

    Directive conformity

    Electromagnetic compatibility

    Directive 2014/30/EU EN 61326-1:2013 (industrial locations)

    Low voltage

    Directive 2014/35/EU EN 61010-1:2010+A1:2019+A1:2019/AC:2019

    Conformity

    Electromagnetic compatibility NE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018

    Degree of protection IEC 60529:1989+A1:1999+A2:2013

    Functional safety IEC/EN 61508:2010

    Input EN 60947-5-6:2000

    Ambient conditions

    Ambient temperature -40 ... 70 °C (-40 ... 158 °F)

    Mechanical specifications

    Degree of protection IP20

    Connection screw terminals

    Mass approx. 150 g

    Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2

    Height 119 mm

    Width 20 mm

    Depth 115 mm

    Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001

    Data for application in connection with hazardous areas

    EU-type examination certificate PTB 00 ATEX 2080

    Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC

    Ex-Hexagon II (1)D [Ex ia Da] IIIC

    Ex-Hexagon I (M1) [Ex ia Ma] I

    Input Ex ia

    Voltage 10.5 V

    Current 13 mA

    Power 34 mW (linear characteristic)

    Supply

    Maximum safe voltage 253 V AC / 125 V DC (Attention! Um is no rated voltage.)

    Output

    Maximum safe voltage 253 V AC (Attention! The rated voltage can be lower.)

    Fault indication output

    Maximum safe voltage 40 V DC (Attention! Um is no rated voltage.)

    Certificate PF 08 CERT 0803

    Marking Ex-Hexagon II (3)G [Ex ic Gc] IIC

    Input Ex ic

    Voltage 10.5 V

    Current 13 mA

    Power 34 mW (linear characteristic)

    Certificate TÜV 99 ATEX 1493 X

    Marking Ex-Hexagon II 3G Ex ec nC IIC T4 Gc

    Galvanic isolation

    Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V

    Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V

    Directive conformity

    Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN IEC 60079-15:2019

    International approvals

    FM approval

    FM certificate FM19US0207X

    Control drawing 116-0035

    UL approval E106378

    Control drawing 116-0473 (cULus)

    Contact loading 250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 30 V DC/2 A resistive load